Skip to main content

Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials

Abstract

Background

The role of intravascular ultrasound (IVUS) in percutaneous coronary interventions (PCI) is still controversial despite several previously published meta-analyses. A meta-analysis to evaluate the controversial role of IVUS-guided PCI with bare-metal stenting was performed and a previous published meta-analysis was re-evaluated in order to clarify the discrepancy between results of these studies.

Methods

A systematic review was performed by an electronic search of the PubMed, Embase and Web of Knowledge databases and by a manual search of reference lists for randomized controlled trials published until April 2011, with clinical outcomes and, at least, six months of clinical follow-up. A meta-analysis based on the intention to treat was performed with the selected studies.

Results

Five studies and 1,754 patients were included. There were no differences in death (OR = 1.86; 95% CI = 0.88-3.95; p = 0.10), non-fatal myocardial infarction (OR = 0.65; 95% CI = 0.27-1.58; p = 0.35) and major adverse cardiac events (OR = 0.74; 95% CI = 0.49-1.13; p = 0.16). An analysis of the previous published meta-analysis strongly suggested the presence of publication bias.

Conclusions

There is no evidence to recommend routine IVUS-guided PCI with bare-metal stent implantation. This may be explained by the paucity and heterogeneity of the studies published so far.

Peer Review reports

Background

Since the first studies of intravascular ultrasound (IVUS) were published in 1989 [14], the technique has been widely used in clinical research and has contributed to technological improvements in interventional cardiology [5]. As a diagnostic tool, IVUS helps in the assessment of coronary lesions classified as moderate based on angiography, especially those located in the left main coronary artery [6, 7], and in the assessment of long lesions, small artery lesions, bifurcations and in-stent restenosis [8, 9]. As an ancillary technique in percutaneous coronary intervention (PCI), IVUS is useful in the evaluation of the target lesion and during stent implantation [10]. In theory, its use should reduce the risk of major adverse cardiovascular events (MACE) because of lower restenosis and stent thrombosis rates.

The first published systematic review evaluated the role of IVUS in PCI as well as its cost-effectiveness and did not show any difference between IVUS and angio-guided PCI [11]. A few years later, a meta-analysis did not show any reduction in death or myocardial infarction (MI) but revealed reductions in repeat revascularization and angiographic restenosis after a six-month follow-up [12]. This was corroborated by another meta-analysis that suggested an improvement in acute post-interventional results (larger minimal luminal diameter) and lower repeat revascularization, angiographic restenosis and MACE rates, but showed no effect on death or MI during the follow-up period of six to thirty months [13].

Since IVUS clinical benefit is still controversial and conclusions of meta-analyses may be misleading due to methodological issues, we performed a meta-analysis to assess the effect of IVUS in PCI with bare-metal stent implantation on clinically relevant outcomes, assessing the presence of publication bias. In addition, a critical review of the last published meta-analysis [13] was performed in order to clarify the discrepancy in the results found in this analysis comparing to medical literature.

Methods

The protocol for the present systematic review was based on the PRISMA Statement [14] and it was registered in the PROSPERO database (CRD42012002767).

Strategy search

We performed an electronic search of PubMed, Embase and Web of Knowledge databases with the following terms: Myocardial Ischemia; Ischemic Heart Disease; Acute Coronary Syndrome; Angina; Coronary Disease; Coronary Artery Disease; Coronary Occlusion; Coronary Thrombosis and Myocardial Infarction, in association with the terms Interventional Ultraso*; Intravascular Ultraso*; Intracoronary Ultraso*; IVUS and ICUS.

A manual search was also performed to retrieve potential articles cited in previous meta-analyses, in review articles and those considered to be relevant by the reviewers. The electronic search, which evaluated the articles included in the databases through April 2011, was limited neither by publication date nor by language.

Eligibility criteria

Only randomized controlled trials that compared IVUS-guided PCI with angiography-guided PCI, with clinical outcomes, and at least six months of clinical follow-up, were included in quantitative synthesis. The clinical outcomes considered were death, nonfatal MI and the combined endpoint of MACE (death, nonfatal MI, or repeat revascularization). For repeat revascularization, a report of any new coronary revascularization (surgical or percutaneous) was considered, regardless of the lesion and of the vessel treated. Surrogate outcomes, such as angiographic outcomes, were not taken into account because these can show a positive result with no effect (or harmful effect) on clinical outcomes [15]. These clinical outcomes (death, nonfatal MI and MACE) were considered primary endpoints in our meta-analysis.

Study selection

The titles and abstracts from the articles retrieved by the search strategy had been independently evaluated by two reviewers (LCP, LLJ). All articles in which IVUS was mentioned were selected. These articles were fully read, and those that met the criteria were included. Disagreements were solved by consensus. If consensus was not achieved, a third reviewer (ALR) defined the question.

Statistical analysis

The intention-to-treat meta-analysis that followed the systematic review was performed by the random-effects model of the Comprehensive Meta-Analysis software (Borenstein M, Hedges L, Higgins J, Rothstein H. Version 2.2.048, Biostat, Englewood NJ, USA 2005), with the odds ratio (OR), 95% confidence intervals and two-sided P-values calculated for each outcome. The analysis of heterogeneity between studies was estimated by the I 2 statistic.

Publication bias evaluation was performed by Duval and Tweedie’s Trim and Fill method [16]. Egger's test was also performed to analyze the impact of several factors on the size of the treatment effect [17]. The small study effect was also evaluated by cumulative analysis (from largest to smallest sample size) and by the one-study-removed method.

Results

Literature search

A total of 4,247 articles in PubMed, 869 in Embase and 4,260 in Web of Knowledge databases were identified. Eight studies were selected according to the inclusion criteria (Figure 1) [1826]. After a comprehensive analysis, three studies were excluded because they used a provisional stenting technique [19, 25, 26], which is no longer performed because of its higher restenosis rate [27]. Table 1 summarizes the clinical and angiographic characteristics of the patients included in the selected studies.

Figure 1
figure 1

Article selection flowchart. Flowchart based on the PRISMA Flow Diagram [14].

Table 1 Patient characteristics

Qualitative study analysis

There were significant differences between the five studies included in the final analysis (Table 2). One of the current indications of IVUS-guided PCI is for patients with long lesions (greater than 15 or 25 mm) [8, 28, 29], who have been excluded from most studies [18, 20, 24]. Unlike the others, the TULIP study excluded those patients who had focal lesions (less than 20 mm in length). Every study but the AVID trial excluded patients with a current or past history of acute coronary syndrome (ACS). In the RESIST study, randomization was performed only after the intervention, which may have caused a selection bias. In the AVID trial, the IVUS analysis was only performed after implantation of the stent, excluding the initial assessment of the target lesion [8].

Table 2 Study characteristics

The criteria for optimal stent implantation were heterogeneous. Only the OPTICUS study used the criteria proposed by the MUSIC study [10]. The majority of patients underwent angiographic assessment after six months (angiographic follow-up) [20, 22, 24]. Another difference between the studies was in the criteria used for MACE. In the RESIST study, MI was not included. In the TULIP study, the MACE criteria included death, nonfatal MI and ischemia-driven target lesion revascularization (TLR). In the AVID trial, the composition of this outcome was not explained. In the other studies, the criteria for repeat revascularization were more comprehensive and included coronary artery bypass grafting (CABG) or a repeated PCI for any reason [18, 20, 21, 24].

Heterogeneity

The heterogeneity among the studies showed intermediate values in nonfatal MI (I 2 = 48.82%) and MACE (I 2 = 57.38%). For death, no heterogeneity was observed among the studies (I 2 = 0%).

Publication bias

We also evaluated the possibility of publication bias (B0) for MACE. Egger’s Test (B0 = −3.43; 95% CI − 6.40 to −0.47, one-tailed P- value 0.02) and the trim and fill test (observed OR 0.74, 95% CI 0.49 to 1.13; two studies imputed: adjusted OR 0.93, 95% CI 0.60 to 1.44) (Figure 2) were positive, suggesting the presence of small studies effects, which can be attributable to differences in design (not detected) or to publication bias.

Figure 2
figure 2

Duval and Tweedie’s trim and fill test. The funnel plot shows the observed studies (white circles) and the imputed studies (black circles) in addition to the observed (white diamond) and adjusted combined effect (black diamond).

Meta-analysis results

A total of 1,754 patients were randomized in five studies. There was no statistically significant difference between the IVUS-guided group and the angiography-guided group (Table 3) for death (OR 1.86, 95% CI 0.88 to 3.95, P = 0.10) (Figure 3-A), nonfatal MI (OR 0.65, 95% CI 0.27 to 1.58, P = 0.35) (Figure 3-B) or MACE (OR 0.74, 95% CI 0.49 to 1.13, P = 0.16) (Figure 3-C).

Table 3 Clinical Outcomes
Figure 3
figure 3

Meta-analysis by outcomes (random effects). (A) Death. (B) Myocardial infarction (MI). (C) Major adverse cardiovascular events (MACE).

Reviewing published data

In order to clarify the discrepancy in MACE results found in this analysis compared to the medical literature, the data of a previously published meta-analysis [13] were re-evaluated (Figure 4). Among the studies selected by that meta-analysis, only two were not included in the present selection because the provisional stenting technique was employed in both of them [19, 25].

Figure 4
figure 4

Original data from the re-evaluated meta-analysis - MACE[13].

A funnel plot analysis was performed along with Egger’s Test (B0 = −3.66, 95% CI − 5.54 to −1.78, one-tailed P-value = 0.002) and the trim and fill test (observed OR 0.70, 95% CI 0.50 to 0.98; three studies imputed: adjusted OR 0.89, 95% CI 0.62 to 1.27), which suggested the presence of publication bias [16, 17].

A cumulative meta-analysis by reverse order of sample size was performed. The results only became positive when the last and smallest study was included in the analysis (Figure 5). Moreover, the one-study-removed analysis showed that the removal of any one of the smaller studies gave a neutral result from the meta-analysis (Figure 6). This makes it plausible to assume that one small unpublished study with negative results would be enough to nullify the effect of that meta-analysis.

Figure 5
figure 5

Cumulative meta-analysis. Each line includes the combined analysis of the corresponding study and the other ones above. The studies were added from largest to smallest sample size.

Figure 6
figure 6

One-study-removed method. Each line excludes the corresponding study from the combined analysis.

Discussion

In this rigorously conducted meta-analysis of randomized controlled trials that compared IVUS-guided PCI with angiography-guided PCI using bare metal stents, we did not find any advantage of the IVUS-guided strategy over the standard method in clinically relevant outcomes. Indeed, we found evidence of publication bias and of significant heterogeneity among the studies regarding the outcomes MI and MACE. These results diverge from the last two meta-analyses on this topic [12, 13], which included studies with provisional stenting, considered surrogate outcomes, and did not evaluate the presence of publication bias. However, they are in concordance with recently published studies of IVUS-guided PCI with drug-eluting stent implantation, which were not associated with significant clinical benefits [30, 31].

Differences between selected studies

The five selected studies have important differences that might lead to completely different outcomes in another context. For example, the exclusion of patients presenting with ACS may have led to a reduction in post-interventional adverse events [3235]. In the AVID trial, pre-interventional IVUS was not performed, which excluded an important phase of the method because one of the roles of IVUS is to assess the target lesion to help in the choice of technique and devices for the PCI [8]. Only the OPTICUS study used the MUSIC study criteria for optimal stent implantation [10], which theoretically could be associated with a lower MACE rate [36]. Angiographic follow-up was performed in most studies, which may have led to an overestimated rate of repeat revascularization, due to the oculo-stenotic reflex [37], which is the predisposition to indicate a PCI for any significant luminal obstruction, despite the presence or absence of myocardial ischemia [38]. The fact that most studies have used more comprehensive criteria for repeat revascularization may have also increased MACE rates [18, 20, 24].

Study biases

The data analysis suggested the presence of publication bias in both meta-analyses. This bias may have led to apparently positive results that could be easily modified by unpublished studies with small sample sizes. It may be harmful because it can maintain or amplify an apparent beneficial effect of the intervention [39].

Significance-chasing bias is an enticing term that refers to the clustering of the most common types of meta-analysis bias, including those in which the apparently negative results remain unpublished (study publication bias and selective outcome reporting bias), those in which negative results become positive (selective analysis reporting bias) and those in which no existing data are presented as positive (fabrication bias) [40, 41].

Selective reporting bias is the most common problem in meta-analyses. In selective outcome reporting bias, specific data with a negative result are omitted from publication. In selective analysis reporting bias, which is even more frequent, a negative result calculated from a pre-determined analysis plan is replaced by a positive result achieved through post hoc data analysis [41].

Another major problem is the potential presence of interests other than scientific truth. This matter becomes critical when the object of the meta-analysis is an industry product, as in the present study, because most of the researches are conducted or funded by manufacturers (Table 4) [42, 43]. There is a current trend towards opposing this practice [44].

Table 4 Study funding and conflicts of interest of the authors of original articles included in this meta-analysis

Meta-analyses have gained prestige over time but they are still considered by some to be an ancillary method, accepted only when it corroborates the point of view of experts and of public policies [41]. They could play a fundamental role in changing (or in supporting) the evidence on relevant issues if conducted properly, with a pre-specified analysis plan and declared conflicts of interest for every study included, in addition to determining and reporting all possible biases.

Limitations

The paucity of randomized controlled trials comparing IVUS-guided PCI and angio-guided PCI and the exclusion of groups with specific lesions (long lesions, small vessels, bifurcations or left main coronary artery) may have masked a possible benefit. The same point applies to the exclusion of patients presenting with ACS, whose rate of cardiovascular events is higher, and PCI, when indicated, may even reduce mortality [3234].

The low statistical power of the present study and of the re-evaluated meta-analysis [13] is due to the presence of heterogeneity and to the possibility of study publication bias. The presence of other biases might be possible but that is even more difficult to prove.

Conclusion

The clinical benefit of IVUS-guided PCI with bare-metal stent implantation could be determined neither by the meta-analysis presented in this study nor by the re-evaluated meta-analysis. This may be explained by the paucity and heterogeneity of the studies published so far. Furthermore, both meta-analyses showed possible publication biases.

Therefore, there is no evidence so far to recommend routine IVUS-guided PCI with bare-metal stent implantation. Studies on specific subgroups and performance of a simple large randomized trial could show different results.

This research was conducted by public funding from the National Council for Scientific and Technological Development (CNPq) (CNPq Project: 559584/2009-1).

References

  1. Yock PG, Linker DT, Angelsen BA: Two-dimensional intravascular ultrasound: technical development and initial clinical experience. J Am Soc Echocardiogr. 1989, 2: 296-304.

    Article  CAS  PubMed  Google Scholar 

  2. Gussenhoven WJ, Essed CE, Frietman P, Mastik F, Lancee C, Slager C, Serruys P, Gerritsen P, Pieterman H, Bom N: Intravascular echographic assessment of vessel wall characteristics: a correlation with histology. Int J Card Imaging. 1989, 4: 105-116. 10.1007/BF01745140.

    Article  CAS  PubMed  Google Scholar 

  3. Hodgson JM, Graham SP, Savakus AD, Dame SG, Stephens DN, Dhillon PS, Brands D, Sheehan H, Eberle MJ: Clinical percutaneous imaging of coronary anatomy using an over-the-wire ultrasound catheter system. Int J Card Imaging. 1989, 4: 187-193. 10.1007/BF01745149.

    Article  CAS  PubMed  Google Scholar 

  4. Roelandt JR, Serruys PW, Bom N, Gussenhoven WG, Lancee CT, Ten HH: Intravascular real-time, two-dimensional echocardiography. Int J Card Imaging. 1989, 4: 63-67. 10.1007/BF01795127.

    Article  CAS  PubMed  Google Scholar 

  5. Colombo A, Hall P, Nakamura S, Almagor Y, Maiello L, Martini G, Gaglione A, Goldberg SL, Tobis JM: Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation. 1995, 91: 1676-1688. 10.1161/01.CIR.91.6.1676.

    Article  CAS  PubMed  Google Scholar 

  6. Abizaid AS, Mintz GS, Abizaid A, Mehran R, Lansky AJ, Pichard AD, Satler LF, Wu H, Kent KM, Leon MB: One-year follow-up after intravascular ultrasound assessment of moderate left main coronary artery disease in patients with ambiguous angiograms. J Am Coll Cardiol. 1999, 34: 707-715. 10.1016/S0735-1097(99)00261-2.

    Article  CAS  PubMed  Google Scholar 

  7. Abizaid AS, Mintz GS, Mehran R, Abizaid A, Lansky AJ, Pichard AD, Satler LF, Wu H, Pappas C, Kent KM, Leon MB: Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings: importance of lumen dimensions. Circulation. 1999, 100: 256-261. 10.1161/01.CIR.100.3.256.

    Article  CAS  PubMed  Google Scholar 

  8. Bourantas CV, Naka KK, Garg S, Thackray S, Papadopoulos D, Alamgir FM, Hoye A, Michalis LK: Clinical indications for intravascular ultrasound imaging. Echocardiography. 2010, 27: 1282-1290. 10.1111/j.1540-8175.2010.01259.x.

    Article  PubMed  Google Scholar 

  9. Orford JL, Denktas AE, Williams BA, Fasseas P, Willerson JT, Berger PB, Holmes DR, PRESTO Investigators: Routine intravascular ultrasound scanning guidance of coronary stenting is not associated with improved clinical outcomes. Am Heart J. 2004, 148: 501-506. 10.1016/j.ahj.2004.03.033.

    Article  PubMed  Google Scholar 

  10. De JP, Mudra H, Figulla H, Almagor Y, Doucet S, Penn I, Colombo A, Hamm C, Bartorelli A, Rothman M, Nobuyoshi M, Yamaguchi T, Voudris V, DiMario C, Makovski S, Hausmann D, Rowe S, Rabinovich S, Sunamura M, van Es GA: Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study). Eur Heart J. 1998, 19: 1214-1223. 10.1053/euhj.1998.1012.

    Article  Google Scholar 

  11. Berry E, Kelly S, Hutton J, Lindsay HS, Blaxill JM, Evans JA, Connelly J, Tisch J, Walker GC, Sivananthan UM, Smith MA: Intravascular ultrasound-guided interventions in coronary artery disease: a systematic literature review, with decision-analytic modelling, of outcomes and cost-effectiveness. Health Technol Assess. 2000, 4: 1-117.

    CAS  PubMed  Google Scholar 

  12. Casella G, Klauss V, Ottani F, Siebert U, Sangiorgio P, Bracchetti D: Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting. Catheter Cardiovasc Interv. 2003, 59: 314-321. 10.1002/ccd.10537.

    Article  PubMed  Google Scholar 

  13. Parise H, Maehara A, Stone GW, Leon MB, Mintz GS: Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in pre-drug-eluting stent era. Am J Cardiol. 2011, 107: 374-382. 10.1016/j.amjcard.2010.09.030.

    Article  PubMed  Google Scholar 

  14. Moher D, Liberati A, Tetzlaff J, Altman DG: Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ. 2009, 339: b2535-10.1136/bmj.b2535.

    Article  PubMed  PubMed Central  Google Scholar 

  15. la Cour JL, Brok J, Gotzsche PC: Inconsistent reporting of surrogate outcomes in randomised clinical trials: cohort study. BMJ. 2010, 341: c3653-10.1136/bmj.c3653.

    Article  PubMed  PubMed Central  Google Scholar 

  16. Sutton AJ, Duval SJ, Tweedie RL, Abrams KR, Jones DR: Empirical assessment of effect of publication bias on meta-analyses. BMJ. 2000, 320: 1574-1577. 10.1136/bmj.320.7249.1574.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  17. Egger M, Smith GD: Bias in location and selection of studies. BMJ. 1998, 316: 61-66. 10.1136/bmj.316.7124.61.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  18. Gil RJ, Pawlowski T, Dudek D, Horszczaruk G, Zmudka K, Lesiak M, Witkowski A, Ochała A, Kubica J, Investigators of Direct Stenting vs Optimal Angioplasty Trial (DIPOL): Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound. The multicenter, randomized trial results. Am Heart J. 2007, 154: 669-675. 10.1016/j.ahj.2007.06.017.

    Article  PubMed  Google Scholar 

  19. Gaster AL, Slothuus SU, Larsen J, Korsholm L, Von BC, Jensen S, Thayssen P, Pedersen KE, Haghfelt TH: Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study. Heart. 2003, 89: 1043-1049. 10.1136/heart.89.9.1043.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  20. Schiele F, Meneveau N, Vuillemenot A, Zhang DD, Gupta S, Mercier M, Danchin N, Bertrand B, Bassand JP: Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: a multicenter, randomized study comparing two strategies–with and without intravascular ultrasound guidance. RESIST Study Group. REStenosis after Ivus guided STenting. J Am Coll Cardiol. 1998, 32: 320-328. 10.1016/S0735-1097(98)00249-6.

    Article  CAS  PubMed  Google Scholar 

  21. Schiele F, Meneveau N, Seronde MF, Caulfield F, Pisa B, Arveux P, Danchin N, Bassand JP: Medical costs of intravascular ultrasound optimization of stent deployment. Results of the multicenter randomized 'REStenosis after Intravascular ultrasound STenting' (RESIST) study. Int J Cardiovasc Intervent. 2000, 3: 207-213.

    Article  PubMed  Google Scholar 

  22. Oemrawsingh PV, Mintz GS, Schalij MJ, Zwinderman AH, Jukema JW, van der Wall EE: Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study). Circulation. 2003, 107: 62-67. 10.1161/01.CIR.0000043240.87526.3F.

    Article  PubMed  Google Scholar 

  23. Russo RJ, Silva PD, Teirstein PS, Attubato MJ, Davidson CJ, DeFranco AC, Fitzgerald PJ, Goldberg SL, Hermiller JB, Leon MB, Ling FS, Lucisano JE, Schatz RA, Wong SC, Weissman NJ, Zientek DM, AVID Investigators: A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial). Circ Cardiovasc Interv. 2009, 2: 113-123. 10.1161/CIRCINTERVENTIONS.108.778647.

    Article  PubMed  Google Scholar 

  24. Mudra H, Di MC, De JP, Figulla HR, Macaya C, Zahn R, Wennerblom B, Rutsch W, Voudris V, Regar E, Henneke KH, Schächinger V, Zeiher A, OPTICUS (OPTimization with ICUS to reduce stent restenosis) Study Investigators: Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study). Circulation. 2001, 104: 1343-1349. 10.1161/hc3701.096064.

    Article  CAS  PubMed  Google Scholar 

  25. Frey AW, Hodgson JM, Muller C, Bestehorn HP, Roskamm H: Ultrasound-guided strategy for provisional stenting with focal balloon combination catheter: results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial. Circulation. 2000, 102: 2497-2502. 10.1161/01.CIR.102.20.2497.

    Article  CAS  PubMed  Google Scholar 

  26. Mueller C, Hodgson JM, Schindler C, Perruchoud AP, Roskamm H, Buettner HJ: Cost-effectiveness of intracoronary ultrasound for percutaneous coronary interventions. Am J Cardiol. 2003, 91: 143-147. 10.1016/S0002-9149(02)03099-0.

    Article  PubMed  Google Scholar 

  27. Al SJ, Holmes DR, Salam AM, Lennon R, Berger PB: Impact of coronary artery stents on mortality and nonfatal myocardial infarction: meta-analysis of randomized trials comparing a strategy of routine stenting with that of balloon angioplasty. Am Heart J. 2004, 147: 815-822. 10.1016/j.ahj.2003.11.025.

    Article  Google Scholar 

  28. Colombo A, De GJ, Moussa I, Kobayashi Y, Karvouni E, Di MC, Di Mario C, Albiero R, Finci L, Moses J: Intravascular ultrasound-guided percutaneous transluminal coronary angioplasty with provisional spot stenting for treatment of long coronary lesions. J Am Coll Cardiol. 2001, 38: 1427-1433. 10.1016/S0735-1097(01)01557-1.

    Article  CAS  PubMed  Google Scholar 

  29. Orford JL, Lerman A, Holmes DR: Routine intravascular ultrasound guidance of percutaneous coronary intervention: a critical reappraisal. J Am Coll Cardiol. 2004, 43: 1335-1342. 10.1016/j.jacc.2003.12.035.

    Article  PubMed  Google Scholar 

  30. Biondi-Zoccai G, Sheiban I, Romagnoli E, De SS, Tamburino C, Colombo A, Burzotta F, Presbitero P, Bolognese L, Paloscia L, Rubino P, Sardella G, Briguori C, Niccoli L, Franco G, Di Girolamo D, Piatti L, Greco C, Capodanno D, Sangiorgi G: Is intravascular ultrasound beneficial for percutaneous coronary intervention of bifurcation lesions? Evidence from a 4,314-patient registry. Clin Res Cardiol. 2011, 100: 1021-1028. 10.1007/s00392-011-0336-x.

    Article  PubMed  Google Scholar 

  31. Jakabcin J, Spacek R, Bystron M, Kvasnak M, Jager J, Veselka J, Kala P, Cervinka P: Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS. Catheter Cardiovasc Interv. 2010, 75: 578-583.

    Article  PubMed  Google Scholar 

  32. Lagerqvist B, Husted S, Kontny F, Stahle E, Swahn E, Wallentin L: 5-year outcomes in the FRISC-II randomised trial of an invasive versus a non-invasive strategy in non-ST-elevation acute coronary syndrome: a follow-up study. Lancet. 2006, 368: 998-1004. 10.1016/S0140-6736(06)69416-6.

    Article  PubMed  Google Scholar 

  33. Fox KA, Poole-Wilson PA, Henderson RA, Clayton TC, Chamberlain DA, Shaw TR, Wheatley DJ, Pocock SJ, Randomized Intervention Trial of unstable Angina Investigators: Interventional versus conservative treatment for patients with unstable angina or non-ST-elevation myocardial infarction: the British Heart Foundation RITA 3 randomised trial. Randomized Intervention Trial of unstable Angina. Lancet. 2002, 360: 743-751. 10.1016/S0140-6736(02)09894-X.

    Article  CAS  PubMed  Google Scholar 

  34. Fox KA, Clayton TC, Damman P, Pocock SJ, de Winter RJ, Tijssen JG, Lagerqvist B, Wallentin L, FIR Collaboration: Long-term outcome of a routine versus selective invasive strategy in patients with non-ST-segment elevation acute coronary syndrome a meta-analysis of individual patient data. J Am Coll Cardiol. 2010, 55: 2435-2445. 10.1016/j.jacc.2010.03.007.

    Article  PubMed  Google Scholar 

  35. Boden WE, O'Rourke RA, Teo KK, Hartigan PM, Maron DJ, Kostuk WJ, Knudtson M, Dada M, Casperson P, Harris CL, Chaitman BR, Shaw L, Gosselin G, Nawaz S, Title LM, Gau G, Blaustein AS, Booth DC, Bates ER, Spertus JA, Berman DS, Mancini GB, Weintraub WS, COURAGE Trial Research Group: Optimal medical therapy with or without PCI for stable coronary disease. N Engl J Med. 2007, 356: 1503-1516. 10.1056/NEJMoa070829.

    Article  CAS  PubMed  Google Scholar 

  36. Serruys PW, Kay IP, Disco C, Deshpande NV, de Feyter PJ: Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months: results of a meta-analysis of the BElgian NEtherlands Stent study (BENESTENT) I, BENESTENT II Pilot. BENESTENT II and MUSIC trials. Multicenter Ultrasound Stent In Coronaries. J Am Coll Cardiol. 1999, 34: 1067-1074. 10.1016/S0735-1097(99)00308-3.

    Article  CAS  PubMed  Google Scholar 

  37. Uchida T, Popma J, Stone GW, Ellis SG, Turco MA, Ormiston JA, Muramatsu T, Nakamura M, Nanto S, Yokoi H, Baim DS: The clinical impact of routine angiographic follow-up in randomized trials of drug-eluting stents: a critical assessment of "oculostenotic" reintervention in patients with intermediate lesions. JACC Cardiovasc Interv. 2010, 3: 403-411. 10.1016/j.jcin.2010.01.010.

    Article  PubMed  Google Scholar 

  38. Topol EJ: Coronary angioplasty for acute myocardial infarction. Ann Intern Med. 1988, 109: 970-980.

    Article  CAS  PubMed  Google Scholar 

  39. Vaitkus PT, Brar C: N-acetylcysteine in the prevention of contrast-induced nephropathy: publication bias perpetuated by meta-analyses. Am Heart J. 2007, 153: 275-280. 10.1016/j.ahj.2006.09.014.

    Article  CAS  PubMed  Google Scholar 

  40. Dawn AG, Balkrishnan R, Feldman SR: Systematic selection bias: a cause of dramatic errors in the inference of treatment effectiveness. J Dermatolog Treat. 2008, 19: 68-71. 10.1080/09546630701870780.

    Article  PubMed  Google Scholar 

  41. Ioannidis JP: Meta-research: The art of getting it wrong. Res Syn Meth. 2010, 1: 169-184. 10.1002/jrsm.19.

    Article  Google Scholar 

  42. Roseman M, Milette K, Bero LA, Coyne JC, Lexchin J, Turner EH, Thombs BD: Reporting of conflicts of interest in meta-analyses of trials of pharmacological treatments. JAMA. 2011, 305: 1008-1017. 10.1001/jama.2011.257.

    Article  CAS  PubMed  Google Scholar 

  43. Moynihan R: It's time to rebuild the evidence base. BMJ. 2011, 342: d3004-10.1136/bmj.d3004.

    Article  PubMed  Google Scholar 

  44. Jorgensen AW, Maric KL, Tendal B, Faurschou A, Gotzsche PC: Industry-supported meta-analyses compared with meta-analyses with non-profit or no support: differences in methodological quality and conclusions. BMC Med Res Methodol. 2008, 8: 60-10.1186/1471-2288-8-60.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lucas Lodi-Junqueira.

Additional information

Competing interest

The authors declare no conflicts of interest in the preparation and in the presentation of this meta-analysis.

Authors’ contributions

LLJ participated in the design of the study, retrieved, reviewed and selected the articles from electronic and manual searches, helped to discuss the results and to draft the manuscript. MRS participated in the design of the study, performed the statistical analysis and helped to discuss the results and to draft the manuscript. LCP retrieved, reviewed and selected the articles from electronic and manual searches. SMBK participated in the design of the study and helped to retrieve articles from electronic searches, to discuss the results and to draft the manuscript. CFSA participated in the design of the study and helped to discuss the results and to draft the manuscript. ALR participated in the coordination of the study, helped to select the articles, to discuss the results and to draft the manuscript. All authors read and approved the final manuscript.

Authors’ original submitted files for images

Rights and permissions

This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Reprints and permissions

About this article

Cite this article

Lodi-Junqueira, L., de Sousa, M.R., da Paixão, L.C. et al. Does intravascular ultrasound provide clinical benefits for percutaneous coronary intervention with bare-metal stent implantation? A meta-analysis of randomized controlled trials. Syst Rev 1, 42 (2012). https://doi.org/10.1186/2046-4053-1-42

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/2046-4053-1-42

Keywords